For Medical

For General X-ray Imaging

Below information is purpose for of development, design and production of medical device systems by implementing our company's products.
Technical and regulatory confirmation/verification is necessary before purchasing and using of these products.

Lineup

Rotating Anode X-ray Tubes 4" X-ray Tube Assemblies

Click photo to enlarge.

Rotating Anode X-ray Tubes 4" X-ray Tube Assemblies
Image Model
Name
Focal
Spot
L/S
Max.
Rating
(0.1 s)
(kW)
Max.
Voltage
(kV)
Max.
Current
(mA)
Anode Housing Assembly Down
load
Angle
(°)
Heat
Capacity
Cooling
Rate
(W)
Rotation
Speed
(min-1)
Housing Type Stator
Type
(kJ) (kHU) X-type FX-type GX-type
E7100X(1) E7100X 0.6/1.2 21.5/55.5 150 400/
800
12 210 300 710 2,700 XH-112V - - XS-AG Links with this mark will open in a separate window.
(524KB)
24/59 3,200
40/100 500/
1,000
9,700
E7255X(1) E7255X 0.6/1.2 18.5/51 150 350/
800
12 210 300 710 2,700 XH-157 - - XS-RB Links with this mark will open in a separate window.
(457KB)
23/60 400/
800
3,200
40/102 500/
1,000
9,700
E7255FX(1) E7255FX 0.6/1.2 18.5/51 150 350/
800
12 210 300 710 2,700 - XH-157 - XS-RB
23/60 400/
800
3,200
40/102 500/
1,000
9,700
E7255GX(1) E7255GX 0.6/1.2 18.5/51 150 350/
800
12 210 300 710 2,700 - - XH-157 XS-RB
23/60 400/
800
3,200
40/102 500/
1,000
9,700
E7254X(1) E7254X 0.6/1.2 21.5/55 150 400/
800
12 285 400 1,180 2,700 XH-157 - - XS-RB Links with this mark will open in a separate window.
(453KB)
23/60 3,200
40/102 500/
1,000
9,700
E7254FX(1) E7254FX 0.6/1.2 21.5/55 150 400/800 12 285 400 1,180 2,700 - XH-157 - XS-RB
23/60 3,200
40/102 500/
1,000
9,700
E7254GX(1) E7254GX 0.6/1.2 21.5/55 150 400/
800
12 285 400 1,180 2,700 - - XH-157 XS-RB
23/60 3,200
40/102 500/
1,000
9,700
E7864X(1) E7864X 0.6/1.2 21.1/51.7 150 340/
765
12 285 400 1,200 2,700 XH-112V - - XS-AG Links with this mark will open in a separate window.
(340KB)
23/58 3,200
40/100 400/
800
9,700
XRR-6653X XRR-6653X 0.3/0.8 6.1/29 150 100/500 12 420 600 2,000 2700 XH-1022 - - XS-AG Links with this mark will open in a separate window.
(422KB)
6.5/30 100/500 3200
12/52 150/700 9700
E7869X(1) E7869X 0.6/1.2 21/53 150 400/
800
12 420 600 1,750 2,700 XH-112V - - XS-AG Links with this mark will open in a separate window.
(465KB)
23/58 400/
900
3,200
40/100 500/
1,000
9,700
Notes
Rotation 2700 (min-1) = 50Hz drive, 3200 (min-1) = 60Hz drive, 9700 (min-1) = 180Hz drive

Rotating Anode X-ray Tubes 3" X-ray Tube Assemblies

Click photo to enlarge.

3″ X-ray Tube Assemblies Lineup Table
Image Model
Name
Focal
Spot
L/S
Max.
Rating
(0.1 s)
(kW)
Max.
Voltage
(kV)
Max.
Current
(mA)
Anode Housing Assembly Down
load
Angle
(°)
Heat
Capacity
Cooling
Rate
(W)
Rotation
Speed
(min-1)
Housing Type Stator
Type
(kJ) (kHU) X-type FX-type GX-type
E7894X(1) E7894X 0.6/1.2 14/29 150 200/
500
12.5 100 140 475 2,700 XH-196 - - XS-BF Links with this mark will open in a separate window.
(270KB)
15/30 3,200
E7240X(1) E7240X 0.6/1.2 14/29 150 200/
500
12 100 140 475 2,700 XH-
121
- - XS-AV Links with this mark will open in a separate window.
(401KB)
15/30 3,200
E7240FX(1) E7240FX 0.6/1.2 14/29 150 200/
500
12 100 140 475 2,700 - XH-126 - XS-AV
15/30 3,200
E7299X(1) E7299X 0.3/1.0 3.4/35.5 150 70/
640
12 100 140 475 2,700 XH-121 - - XS-AV Links with this mark will open in a separate window.
(385KB)
3.7/39 3,200
E7299FX(1) E7299FX 0.3/1.0 3.4/35.5 150 70/
640
12 100 140 475 2,700 - XH-126 - XS-AV
3.7/39 3,200
E7239X(1) E7239X 1.0/2.0 21/42.5 125 340/
570
16 100 140 475 2,700 XH-121 - - XS-AV Links with this mark will open in a separate window.
(420KB)
22.5/47 3,200
E7239FX(1) E7239FX 1.0/2.0 21/42.5 125 340/
570
16 100 140 475 2,700 - XH-126 - XS-AV
22.5/47 3,200
E7239GX(1) E7239GX 1.0/2.0 21/42.5 125 340/
570
16 100 140 475 2,700 - - XH-150 XS-AV
22.5/47 3,200
E7843X(1) E7843X 0.6/1.2 20/46 150 370/
760
12 111 150 475 2,700 XH-121 - - XS-BA Links with this mark will open in a separate window.
(384KB)
22/50 3,200
E7242X(1) E7242X 0.6/1.5 16.5/47 125 290/
800
14 142 200 475 2,700 XH-121 - - XS-RA Links with this mark will open in a separate window.
(422KB)
18/50 3,200
E7242FX(1) E7242FX 0.6/1.5 16.5/47 125 290/
800
14 142 200 475 2,700 - XH-126 - XS-RA
18/50 3,200
E7242GX(1) E7242GX 0.6/1.5 16.5/47 125 290/
800
14 142 200 475 2,700 - - XH-150 XS-RA
18/50 3,200
E7876X(1) E7876X 0.6/1.2 20/50 150 300/
700
12 163 230 750 2,700 XH-121 - - XS-RA Links with this mark will open in a separate window.
(384KB)
22/54 3,200
E7833X(1) E7833X 0.3/0.6 7.4/20 125 100/
250
10 210 300 870 2,700 XH-183 - - XS-BB Links with this mark will open in a separate window.
(269KB)
8/22 3,200
E7252X(1) E7252X 0.6/1.2 14.2/40.6 150 300/
800
12 210 300 475 2,700 XH-106V - - XS-RA/
XS-AL
Links with this mark will open in a separate window.
(388KB)
16/44.6 3,200
27/75 400/
1,000
9,700
E7252FX(1) E7252FX 0.6/1.2 14.2/40.6 150 300/
800
12 210 300 475 2,700 - XH-181 - XS-
RA/
XS-AL
16/44.6 3,200
27/75 400/
1,000
9,700
E7252GX(1) E7252GX 0.6/1.2 14.2/40.6 150 300/
800
12 210 300 475 2,700 - - XH-180 XS-
RA/
XS-AL
16/44.6 3,200
27/75 400/
1,000
9,700
E7884X(1) E7884X 0.6/1.2 20/50 150 300/
700
12 210 300 870 2,700 XH-121 - - XS-AL Links with this mark will open in a separate window.
(448KB)
22/54 3,200
E7884FX(1) E7884FX 0.6/1.2 20/50 150 300/
700
12 210 300 870 2,700 - XH-
126
- XS-AL
22/54 3,200
F7884GX(1) E7884GX 0.6/1.2 20/50 150 300/
700
12 210 300 870 2,700 - - XH-150 XS-AL
22/54 3,200
E7886X(1) E7886X 0.7/1.3 15/36 150 280/
550
16 210 300 870 2,700 XH-121 - - XS-AL Links with this mark will open in a separate window.
(413KB)
17/40 3,200
E7886FX(1) E7886FX 0.7/1.3 15/36 150 280/
550
16 210 300 870 2,700 - XH-
126
- XS-AL
17/40 3,200
XRR-3331X XRR-3331X 0.6/1.2 20/50 150 300/700 12 210 300 870 2700 XH-121 - - XS-AL Links with this mark will open in a separate window.
(435KB)
22/54 3200
32/78 400/1000 9700
XRR-3332X XRR-3332X 0.6/1.2 18/42 150 300/600 14 210 300 870 2700 XH-1023 - - XS-AL Links with this mark will open in a separate window.
(834KB)
20/46 3200
Notes
Rotation 2700 (min-1) = 50Hz drive, 3200 (min-1) = 60Hz drive, 9700 (min-1) = 180Hz drive

Rotating Anode X-ray Tubes Rotating Anode X-ray Tubes

Click photo to enlarge.

Rotating Anode X-ray Tubes
Image Model
Name
Focal
spot
S/L
Max.
Rating
Max.
Voltage
Max.
Current
Anode Circuit Dimension
(mm)
Length×Diameter
Down
load
Angle Diameter Heat
Capacity
Cooling
Rate
Rotation
(kW)
at 0.1s
(kV) (mA) (°) (mm) (kJ) (kHU) (W) (min-1)
- XRR-3352 0.3/0.7 7/22.5 125 140/400 10.0 74 210 300 870 2700 T,C 216×95 -
7.5/25 3200

X-ray Flat Panel Detectors

Click photo to enlarge.

X-ray Flat Panel Detectors
Image Inch Type Model Name Useful Entrance
Field Size
Number of
Pixels
Pitch
(μm)
Interface Application Down
load
Wireless-Type
FDXA3543RPW 14×17 FDXA3543RPW 350×426 2800×3408 125 Wireless/Wired
(Ethernet 1000 Base-T)
Radiography
(Static image)
Links with this mark will open in a separate window.
(640KB)
FDXA4343RPW 17×17 FDXA4343RPW 415×426 3320×3408 125 Links with this mark will open in a separate window.
(537KB)
Tethered-Type
FDXA3543RP 14×17 FDXA3543RP 346x426 2466×3040 140 Ethernet
(1000 Base-T)

Advanced AED
Radiography
(Static image)

Cable replaceable
Links with this mark will open in a separate window.
(399KB)
FDXA3543RPS Radiography
(Static image)

Cable replaceable
DC power input type
Links with this mark will open in a separate window.
(408KB)
Fixed-Type
FDX4343R 17×17 FDX4343R 430×439 3008×3072 143 Ethernet
(1000 Base-T)
Radiography
(Static image)
Links with this mark will open in a separate window.
(861KB)
Fixed Slim -Type
FDXA4343R 17×17 FDXA4343R 426×425 3040×3036 140 Ethernet
(1000 Base-T)

Advanced AED
Radiography
(Static image)
Links with this mark will open in a separate window.
(561KB)
FDXA4343R-HD Ethernet
(1000 Base-T)

Advanced AED
Radiography
(Static image)

High DQE version
Links with this mark will open in a separate window.
(559KB)

Inquiry About Products