X-ray Image Intensifiers

Medical

Below information is purpose for of development, design and production of medical device systems by implementing our company's products. Technical and regulatory confirmation/verification is necessary before purchasing and using of these products.

The input window of the image intensifier(I.I.) is vapor-deposited with a thick film of extremely fine pillar crystal phosphor, which reduces light diffusion and improves X-ray conversion efficiency.

X-ray Image Intensifiers Medical

Lineup

4-inch

Click photo to enlarge.

Medical X-ray Image Intensifiers 4-inch Lineup Table
Image Model Name Nominal Entrance
Field Size
Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M
mode
Nor-
mal
mode
M
mode
10% area 10 mm
dia.
typical Overall length Mounting Surface
E5877J-P1 E5877J
-P1
100 mm
min.
95 mm min. 50 ±5 mm 20 ±1 77 110 22:1 18:1 42% 226
±3
mm
Side of the
image
intensifier
C-arm/
Fluoro
table
-

6-inch

Click photo to enlarge.

Medical X-ray Image Intensifiers 6-inch Lineup Table
Image Model Name Nominal Entrance
Field Size
Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M
mode
Nor-
mal
mode
M
mode
10% area 10 mm
dia.
typical Overall length Mounting Surface
E5863SD-P4A E5870SD
-P6A
150 mm
min.
140 mm min. 105 ±5 mm 20 ±0.5 66 77 30:1 20:1 42% 276 ±5 mm Side of the image intensifier & Front of the image intensifier MiniC-arm/CBCT -

9-inch

Click photo to enlarge.

Medical X-ray Image Intensifiers 9-inch Lineup Table
Image Model
Name
Nominal Entrance Field Size Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M1
mode
M2
mode
Nor-
mal
mode
M1
mode
M2
mode
10% area 10 mm dia. typical Overall length Mounting Surface
E5764SD-P4A E5764SD
-P4A
230 mm min. 215 mm min. 160 ±5 mm 120 ±5 mm 20 ±0.5 48 56 66 25:1 16:1 65% 338 ±5
mm
Same side as the power supply box & Front of the image intensifier C-arm/
Fluoro
table
-
E5830SD
-P4A
25 ±0.5 52 58 68 30:1 19:1 Links with this mark will open in a separate window.
(291KB)
E5764SD-P7A E5764SD
-P7A
20 ±0.5 48 56 66 25:1 16:1 341 ±5 mm Same side as the power supply box C-arm Links with this mark will open in a separate window.
(705KB)
E5830SD
-P7A
25 ±0.5 52 58 68 30:1 19:1 Links with this mark will open in a separate window.
(705KB)

12-inch

Click photo to enlarge.

Medical X-ray Image Intensifiers 12-inch Lineup Table
Image Model
Name
Nominal Entrance Field Size Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M1
mode
M2
mode
Nor-
mal
mode
M1
mode
M2
mode
10% area 10 mm
dia.
typical Overall length Mounting Surface
E5765SD-P2A E5765SD
-P2A
310
mm
min.
290 mm min. 215 ±5 mm 160 ±5 mm 25 ±0.5 46 50 56 24:1 15:1 65% 434.5
±5
mm
Side of the image intensifier
&
Front of the image intensifier
C-arm/
Fluoro
table
-
E5796SD
-P2A
30:1 18:1 Links with this mark will open in a separate window.
(275KB)

The product information shown in the lineup table is not intended as an advertisement or inducement for the Japanese domestic market.