For Medical

For X-ray Fluorography

Below information is purpose for of development, design and production of medical device systems by implementing our company's products.
Technical and regulatory confirmation/verification is necessary before purchasing and using of these products.

Lineup

Rotating Anode X-ray Tube Assemblies

4" X-ray Tube Assemblies

Click photo to enlarge.

4" X-ray Tube Assemblies 
Image Model
Name
Focal
Spot
L/S
Max.
Rating
(0.1 s)
(kW)
Max.
Voltage
(kV)
Max.
Current
(mA)
Anode Housing Assembly Down
load
Angle
(°)
Heat
Capacity
Cooling
Rate
(W)
Rotation
Speed
(min-1)
Housing Type Stator
Type
(kJ) (kHU) X-type FX-type GX-type
E7100X(1) E7100X 0.6/1.2 21.5/55.5 150 400/
800
12 210 300 710 2,700 XH-112V - - XS-AG Links with this mark will open in a separate window.
(524KB)
24/59 3,200
40/100 500/
1,000
9,700
E7255X(1) E7255X 0.6/1.2 18.5/51 150 350/
800
12 210 300 710 2,700 XH-157 - - XS-RB Links with this mark will open in a separate window.
(457KB)
23/60 400/
800
3,200
40/102 500/
1,000
9,700
E7255FX(1) E7255FX 0.6/1.2 18.5/51 150 350/
800
12 210 300 710 2,700 - XH-157 - XS-RB
23/60 400/
800
3,200
40/102 500/
1,000
9,700
E7254X(1) E7254X 0.6/1.2 21.5/55 150 400/
800
12 285 400 1,180 2,700 XH-157 - - XS-RB Links with this mark will open in a separate window.
(453KB)
23/60 3,200
40/102 500/
1,000
9,700
E7254FX(1) E7254FX 0.6/1.2 21.5/55 150 400/800 12 285 400 1,180 2,700 - XH-157 - XS-RB
23/60 3,200
40/102 500/
1,000
9,700
E7254GX(1) E7254GX 0.6/1.2 21.5/55 150 400/
800
12 285 400 1,180 2,700 - - XH-157 XS-RB
23/60 3,200
40/102 500/
1,000
9,700
E7864X(1) E7864X 0.6/1.2 21.1/51.7 150 340/
765
12 285 400 1,200 2,700 XH-112V - - XS-AG Links with this mark will open in a separate window.
(340KB)
23/58 3,200
40/100 400/
800
9,700
E7869X(1) E7869X 0.6/1.2 21/53 150 400/
800
12 420 600 1,750 2,700 XH-112V - - XS-AG Links with this mark will open in a separate window.
(465KB)
23/58 400/
900
3,200
40/100 500/
1,000
9,700
Notes
Rotation 2700 (min-1) = 50Hz drive, 3200 (min-1) = 60Hz drive, 9700 (min-1) = 180Hz drive

3" X-ray Tube Assemblies

Click photo to enlarge.

3" X-ray Tube Assemblies
Image Model
Name
Focal
Spot
L/S
Max.
Rating
(0.1 s)
(kW)
Max.
Voltage
(kV)
Max.
Current
(mA)
Anode Housing Assembly Down
load
Angle
(°)
Heat
Capacity
Cooling
Rate
(W)
Rotation
Speed
(min-1)
Housing Type Stator
Type
(kJ) (kHU) X-type FX-type GX-type
E7242X(1) E7242X 0.6/1.5 16.5/47 125 290/
800
14 142 200 475 2,700 XH-121 - - XS-RA Links with this mark will open in a separate window.
(422KB)
18/50 3,200
E7242FX(1) E7242FX 0.6/1.5 16.5/47 125 290/
800
14 142 200 475 2,700 - XH-126 - XS-RA
18/50 3,200
E7876X(1) E7876X 0.6/1.2 20/50 150 300/
700
12 163 230 750 2,700 XH-121 - - XS-RA Links with this mark will open in a separate window.
(384KB)
22/54 3,200
E7252X(1) E7252X 0.6/1.2 14.2/40.6 150 300/
800
12 210 300 475 2,700 XH-106V - - XS-RA/
XS-AL
Links with this mark will open in a separate window.
(388KB)
16/44.6 3,200
27/75 400/
1,000
9,700
E7252FX(1) E7252FX 0.6/1.2 14.2/40.6 150 300/
800
12 210 300 475 2,700 - XH-181 - XS-
RA/
XS-AL
16/44.6 3,200
27/75 400/
1,000
9,700
E7252GX(1) E7252GX 0.6/1.2 14.2/40.6 150 300/
800
12 210 300 475 2,700 - - XH-180 XS-
RA/
XS-AL
16/44.6 3,200
27/75 400/
1,000
9,700
E7884X(1) E7884X 0.6/1.2 20/50 150 300/
700
12 210 300 870 2,700 XH-121 - - XS-AL Links with this mark will open in a separate window.
(448KB)
22/54 3,200
E7886X(1) E7886X 0.7/1.3 15/36 150 280/
550
16 210 300 870 2,700 XH-121 - - XS-AL Links with this mark will open in a separate window.
(413KB)
17/40 3,200
XRR-3331X XRR-3331X 0.6/1.2 20/50 150 300/700 12 210 300 870 2700 XH-121 - - XS-AL Links with this mark will open in a separate window.
(435KB)
22/54 3200
32/78 400/1000 9700
Notes
Rotation 2700 (min-1) = 50Hz drive, 3200 (min-1) = 60Hz drive, 9700 (min-1) = 180Hz drive

X-ray Image Intensifiers

9-inch

Click photo to enlarge.

X-ray Image Intensifiers 9-inch
Image Model Name Nominal Entrance Field Size Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M1
mode
M2
mode
Nor-
mal
mode
M1
mode
M2
mode
10% area 10 mm dia. typical Overall length Mounting Surface
E5764SD-P4A E5764SD
-P4A
230 mm min. 215 mm min. 160 ±5 mm 120 ±5 mm 20 ±0.5 48 56 66 25:1 16:1 65% 338 ±5
mm
Same side as the power supply box
&
Front of the image intensifier
C-arm/
Fluoro table
-
E5830SD
-P4A
25 ±0.5 52 58 68 30:1 19:1 Links with this mark will open in a separate window.
(291KB)

12-inch

Click photo to enlarge.

X-ray Image Intensifiers 12-inch
Image Model Name Nominal Entrance Field Size Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M1
mode
M2
mode
Nor-
mal
mode
M1
mode
M2
mode
10% area 10 mm dia. typical Overall length Mounting Surface
E5765SD-P2A E5765SD
-P2A
310
mm
min.
290 mm min. 215 ±5 mm 160 ±5 mm 25 ±0.5 46 50 56 24:1 15:1 65% 434.5
±5
mm
Side of the image intensifier
&
Front of the image intensifier
C-arm/
Fluoro
table
-
E5796SD
-P2A
30:1 18:1 Links with this mark will open in a separate window.
(275KB)

Inquiry About Products