For Mobile Surgical X-ray System (Mobile C-arm)
Below information is purpose for of development, design and production of medical device systems by
implementing our company's products.
Technical and regulatory confirmation/verification is necessary before purchasing and using of these
products.
Lineup
Stationary Anode X-ray Tubes
Click photo to enlarge.
Image | Model Name (Series) |
Focal Spot |
Max. Rating (1 s) (W) |
Max. Voltage (kV) |
Max. Current (mA) |
Circuit | Target Angle (degree) |
Anode | Provide | Down load |
|||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
without | S | SB | |||||||||||
Heat Capacity (kJ) |
Cooling Rate (W) |
Dimensions(mm) Length×Diameter |
|||||||||||
- | DF-151 | 0.5/ 1.5 |
680/ 3,200 |
110 | 15/60 | C | 16 | 28 | 265 | 139×52 | 145×60 | 145×64 |
(326KB) |
DF-151R | 0.5/ 1.5 |
680/ 3,200 |
110 | 15/60 | C | 16 | 35.5 | 600 | 160×52 | - | 166×64 | ||
- | DF-161R | 0.5/ 1.6 |
700/ 4,000 |
125 | 15/60 | C | 16 | 35.5 | 600 | 160×52 | - | 176×64 |
(181KB) |
- | DF-183 | 0.5/1.8 | 1000/4200 | 125 | 15/100 | C | 16 | 28 | 265 | 139×52 | - | 155×64 |
(214KB) |
- | DF-183R | 0.5/1.8 | 1000/4200 | 125 | 15/100 | C | 16 | 35.5 | 600 | 160×52 | - | 176×64 | |
- | DF-281 | 0.6/2.8 | 560/1750 | 125 | 15/100 | C | 15 | 28 | 265 | 139×52 | - | - |
(229KB) |
- Notes
- Circuit
C : Constant Potential High-Voltage Generator(All tubes are center grounded)
SF : Two-peak high-voltage generator
AC : One-Peak High-Voltage Generator(Self-rectified)
X-ray Image Intensifiers
6-inch
Click photo to enlarge.
9-inch
Click photo to enlarge.
Image | Model Name | Nominal Entrance Field Size | Useful Entrance Field Size |
Output Image Dia- meter (mm) |
Central Resolution (Lp/cm) typical |
Contrast Ratio typical |
DQE (IEC Stan- dard) |
Mechanical | Appli- cation |
Download | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Normal mode |
Normal mode |
M1 mode |
M2 mode |
Nor- mal mode |
M1 mode |
M2 mode |
10% area | 10 mm dia. | typical | Overall length | Mounting Surface | |||||
E5764SD -P4A |
230 mm min. | 215 mm min. | 160 ±5 mm | 120 ±5 mm | 20 ±0.5 | 48 | 56 | 66 | 25:1 | 16:1 | 65% | 338 ±5 mm |
Same side as the power supply box & Front of the image intensifier | C-arm/ Fluoro table |
- | |
E5830SD -P4A |
25 ±0.5 | 52 | 58 | 68 | 30:1 | 19:1 |
(291KB) |
|||||||||
E5764SD -P7A |
20 ±0.5 | 48 | 56 | 66 | 25:1 | 16:1 | 341 ±5 mm | Same side as the power supply box | C-arm |
(705KB) |
||||||
E5830SD -P7A |
25 ±0.5 | 52 | 58 | 68 | 30:1 | 19:1 |
(705KB) |
12-inch
Click photo to enlarge.
Image | Model Name | Nominal Entrance Field Size | Useful Entrance Field Size |
Output Image Dia- meter (mm) |
Central Resolution (Lp/cm) typical |
Contrast Ratio typical |
DQE (IEC Stan- dard) |
Mechanical | Appli- cation |
Download | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Normal mode |
Normal mode |
M1 mode |
M2 mode |
Nor- mal mode |
M1 mode |
M2 mode |
10% area | 10 mm dia. | typical | Overall length | Mounting Surface | |||||
E5796SD -P2A |
310 mm min. |
290 mm min. | 215 ±5 mm | 160 ±5 mm | 25 ±0.5 | 46 | 50 | 56 | 30:1 | 18:1 | 65% | 434.5 ±5 mm |
Side of the image intensifier & Front of the image intensifier |
C-arm/ Fluoro table |
(275KB) |