For Medical

For Cardiovascular X-ray System and X-ray Angiography

Below information is purpose for of development, design and production of medical device systems by implementing our company's products.
Technical and regulatory confirmation/verification is necessary before purchasing and using of these products.

Lineup

Rotating Anode X-ray Tubes X-ray Tube Assemblies for Angiography Systems

Click photo to enlarge.

Rotating Anode X-ray Tubes X-ray Tube Assemblies for Angiography Systems
Image Model
Name
Focal
Spot
L/M/S
Max.
Rating
(0.1s)
(kW)
Long
-time
Maxi
mum
Input
(W)
Max. Voltage
(kV)
Max.
Tube
Current
(mA)
Anode Housing Assembly Down
load
Angle
(°)
Diameter
(mm)
Max.
Heat Content
Cooling
Rate
(W)
Max.
Rotation
Speed
(min-1)
Max.
Heat
Dissi
pation
(W)
Housing
Type
Weight*
(kg)
R F
Conti
nuous
Grid
Control
(kJ) (kHU)
E79016X(L) E79016X L 1.0 100 2,200 125 125 120 1,100 11 140 2,130 3,000 5,500 9,000 3,500 XH-177 46 Links with this mark will open in a separate window.
(328KB)
M 0.6 48 650
S 0.3 17 180
E7902X(L) E7902X L 0.8 90 2,200 125 125 110 950 8 140 2,130 3,000 5,500 9,000 3,500 XH-177 46 Links with this mark will open in a separate window.
(334KB)
M 0.5 45 600
S
E79036X(L) E79036X L 0.8 80 2,200 125 125 120 800 8 120 1,500 2,100 4,500 9,000 3,000 XH-1008 38 Links with this mark will open in a separate window.
(332KB)
S 0.5 44 470
E79039X(L) E79039X L 1.0 80 2,200 125 125 120 800 11 120 1,500 2,100 4,500 9,000 3,000 XH-1008 38 Links with this mark will open in a separate window.
(313KB)
S 0.6 43 480
Notes
* Without heat exchanger.

X-ray Image Intensifiers Dental/Medical 12-inch

Click photo to enlarge.

X-ray Image Intensifiers Dental/Medical 12-inch
Image Model Name * Nominal Entrance Field Size Useful Entrance
Field Size
Output
Image
Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M1
mode
M2
mode
Nor-
mal
mode
M1
mode
M2
mode
10% area 10 mm dia. typical Overall length Mounting Surface
E5796SD-P2A E5796SD-
P2A
310
mm
min.
290 mm min. 215 ±5 mm 160 ±5 mm 25 ±0.5 46 50 56 30:1 18:1 65% 434.5
±5
mm
Side of the image intensifier
&
Front of the image intensifier
C-arm/
Fluoro
table
Links with this mark will open in a separate window.
(275KB)
Notes
* Products with a model name ending in "A" are 24 Vdc input type.
* Products with a model name not ending in "A" are 100-240 Vac input type.

X-ray Image Intensifiers Dental/Medical 16-inch

Click photo to enlarge.

X-ray Image Intensifiers Dental/Medical 16-inch
Image Model Name * Nomi-
nal
Ent-
rance
Field
Size
Useful Entrance
Field Size
Out-
put Image Dia-
meter
(mm)
Central Resolution
(Lp/cm) typical
Contrast Ratio
typical
DQE
(IEC
Stan-
dard)
Mechanical Appli-
cation
Download
Normal
mode
Normal
mode
M1
mode
M2
mode
M3
mode
Nor-
mal
mode
M1
mode
M2
mode
M3
mode
10% area 10 mm dia. typi-
cal
Overall
length
Mounting Surface
E5876SD-P1A E5876SD-
P1A
400
±5
mm
360 ±5
mm
290 ±5 mm 215 ±5 mm 160 ±5 mm 35
±0.5
46 50 56 65 30:1 typ. 18:1 typ. 65% typ. 520
±3
mm
Side of the image intensifier
&
Front of the image intensifier
C-arm/
Fluoro
table
-
E5876SD-P2A E5876SD-
P2A
Front of the image intensifier Fluoro
table
-
Notes
* Products with a model name ending in "A" are 24 Vdc input type.
* Products with a model name not ending in "A" are 100-240 Vac input type.

Inquiry About Products