For Medical
For X-ray Angiography
Below information is purpose for of development, design and production of medical device systems by
implementing our company's products.
Technical and regulatory confirmation/verification is necessary before purchasing and using of these
products.
Lineup
X-ray Tube Assemblies for Angiography Systems
Click photo to enlarge.
Image | Model Name |
Focal Spot L/M/S |
Max. Rating (0.1s) (kW) |
Long -time Maxi mum Input (W) |
Max. Voltage (kV) |
Max. Tube Current (mA) |
Anode | Housing Assembly | Down load |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Angle (°) |
Diameter (mm) |
Max. Heat Content |
Cooling Rate (W) |
Max. Rotation Speed (min-1) |
Max. Heat Dissi pation (W) |
Housing Type |
Weight* (kg) |
||||||||||||
R | F | ||||||||||||||||||
Conti nuous |
Grid Control |
(kJ) | (kHU) | ||||||||||||||||
E79016X | L | 1.0 | 100 | 2,200 | 125 | 125 | 120 | 1,100 | 11 | 140 | 2,130 | 3,000 | 5,500 | 9,000 | 3,500 | XH-177 | 46 |
(328KB) |
|
M | 0.6 | 48 | 650 | ||||||||||||||||
S | 0.3 | 17 | 180 | ||||||||||||||||
E7902X | L | 0.8 | 90 | 2,200 | 125 | 125 | 110 | 950 | 8 | 140 | 2,130 | 3,000 | 5,500 | 9,000 | 3,500 | XH-177 | 46 |
(334KB) |
|
M | 0.5 | 45 | 600 | ||||||||||||||||
S | |||||||||||||||||||
E79036X | L | 0.8 | 80 | 2,200 | 125 | 125 | 120 | 800 | 8 | 120 | 1,500 | 2,100 | 4,500 | 9,000 | 3,000 | XH-1008 | 38 |
(332KB) |
|
S | 0.5 | 44 | 470 | ||||||||||||||||
E79039X | L | 1.0 | 80 | 2,200 | 125 | 125 | 120 | 800 | 11 | 120 | 1,500 | 2,100 | 4,500 | 9,000 | 3,000 | XH-1008 | 38 |
(313KB) |
|
S | 0.6 | 43 | 480 |
- Notes
- * Without heat exchanger.
X-ray Image Intensifiers
12-inch
Click photo to enlarge.
Image | Model Name * | Nominal Entrance Field Size | Useful Entrance Field Size |
Output Image Dia- meter (mm) |
Central Resolution (Lp/cm) typical |
Contrast Ratio typical |
DQE (IEC Stan- dard) |
Mechanical | Appli- cation |
Download | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Normal mode |
Normal mode |
M1 mode |
M2 mode |
Nor- mal mode |
M1 mode |
M2 mode |
10% area | 10 mm dia. | typical | Overall length | Mounting Surface | |||||
E5796SD -P2A |
310 mm min. |
290 mm min. | 215 ±5 mm | 160 ±5 mm | 25 ±0.5 | 46 | 50 | 56 | 30:1 | 18:1 | 65% | 434.5 ±5 mm |
Side of the image intensifier & Front of the image intensifier |
C-arm/ Fluoro table |
(275KB) |
Inquiry About Products
USA:+1-800-970-7227
Europe:+31-20-399-9087
Japan:+81-44-739-6502
China(Shanghai):+86-21-6361-0077
China(Beijing):+86-10-8525-8277