Industrial X-ray Tubes

Click photo to enlarge.

Industrial X-ray Tubes
Image Model Name Target
Material
Focal
Spot
(mm)
Max.
Rating
(W)
Max.
Voltage
(kV)
Max.
Current
(mA)
Circuit Ground Target
Angle
(°)
Be
Thickness
(mm)
Dimensions
Length
x
Diameter
(mm)
Appli
cation
Down
load
- I-2118B W 1×0.7 55 55 1 C N 20 Glass1.7 96×30.5 F …Links with this mark will open in a separate window.
(157KB)
- E7690 W 1×1 350 75 8 C CG 20 1 185×62 F …Links with this mark will open in a separate window.
(225KB)
I-2112B I-2112B Rh 0.8 50 50 1 C CG 33 0.05 96×33 A …Links with this mark will open in a separate window.
(182KB)
I-2113A I-2113A Mo 0.15 75 50 1.5 C CG 10 0.05 96×33 A,T …Links with this mark will open in a separate window.
(163KB)
I-2115C I-2115C W,Mo 0.15 75 50 1.5 C CG 10 0.2 96×33 A,T -
I-2122A I-2122A W 0.15x0.1 50 50 1 C CG 16 0.2 96×30.5 A,T …Links with this mark will open in a separate window.
(172KB)
I-2123 I-2123 W 0.1 50 60 1.2 C CG 10 0.2 96×30.5 N …Links with this mark will open in a separate window.
(166KB)
- I-317 W 0.1 50 100 0.83 C CG 10 0.5 180×62 N …Links with this mark will open in a separate window.
(170KB)
Notes
Circuit : C=DC1, S=self-rectification
Ground : AG=Anode ground, CG=Cathode ground
Application : T=Thicknessmeter, A=Analysis, N=Nondestructive
* : Input peak power (1 pluse)

X-ray Image Intensifiers

4-inch

Click photo to enlarge.

X-ray Image Intensifiers 4-inch Lineup
Image Model Name Material of
Input Window
Application Central Resolution Contrast Ratio
Normal mode
(Lp/cm typ.)
Magnified mode
(Lp/cm typ.)
10% area
(typ.)
10 mm dia.
(typ.)
E5877J-P1AK Al
(Aluminium)
Standard 4" mode: 77 2" mode: 110 22:1 18:1
E5877J-P1K
E5877K-P1K High-Resolution 4" mode: 92 2" mode: 125 26:1 19:1
E5877RE-P1K High-Speed Response 4" mode: 77 2" mode: 110 22:1 18:1
E5889BE-P1K Be
(Beryllium)
Standard 4" mode: 77 2" mode: 110 22:1 18:1
E5889K-P1K High-Resolution 4" mode: 92 2" mode: 125 26:1 19:1
E5889BP-P1K High-Speed Response 4" mode: 77 2" mode: 110 22:1 18:1

6-inch

Click photo to enlarge.

X-ray Image Intensifiers 6-inch Lineup
Image Model Name Material of
Input Window
Application Central Resolution Contrast Ratio
Normal mode
(Lp/cm typ.)
Magnified mode
(Lp/cm typ.)
10% area
(typ.)
10 mm dia.
(typ.)
E5870SD-P6AK Al
(Aluminium)
High-Resolution 6" mode: 66 4" mode: 77 30:1 20:1

9-inch

Click photo to enlarge.

X-ray Image Intensifiers 9-inch Lineup
Image Model Name Material of
Input Window
Application Central Resolution Contrast Ratio
Normal mode
(Lp/cm typ.)
Magnified mode
(Lp/cm typ.)
10% area
(typ.)
10 mm dia.
(typ.)
E5764SD-P4K Al
(Aluminium)
Standard 9" mode: 48 6" mode: 56 25:1 16:1
4.5" mode: 66
E5830SD-P4AK High-Resolution 9" mode: 52 6" mode: 58 30:1 19:1
4.5" mode: 68

12-inch

Click photo to enlarge.

X-ray Image Intensifiers 12-inch Lineup
Image Model Name Material of
Input Window
Application Central Resolution Contrast Ratio
Normal mode
(Lp/cm typ.)
Magnified mode
(Lp/cm typ.)
10% area
(typ.)
10 mm dia.
(typ.)
E5796SD-P2AK Al
(Aluminium)
High-Resolution 12" mode: 46 9" mode: 50 30:1 18:1
6" mode: 56